Form the terminal for restaurants |
|||
|
|
|||
|
The terminal comes from origin with
a software for restaurants. To form it, the following instrucions must be
followed:
Verify radio parameters Option 1. In the first terminals this values
were not configurable. The first value was always 91 and the second always
7. Because of a modification on the antenna's software the second value by
default became 15, which provocated an incompatibility. Recent terminals
can always be formed with the value 7, but not on the contrary. |
|||
|
Radio Module (1stValue) |
Value on the terminal (2nd Value) |
Value in the Antenna |
|
|
Radiometrix type 91 module |
7 |
40000 |
|
|
Type 91 Radiometrix module |
15 |
20000 |
|
|
Type 52 Radionordic |
15 |
20000 |
|
|
|
|||
|
To form the antenna's value the Devkit mut be used. Antenna's value by default is always 20000. |
|||
|
|
|||
|
On the terminal, option 2 must be selected and 'Ins' key pressed in order to make the terminal start automatically with the 2 option. |
|||
|
At this moment, the terminal has
got the restaurants program installed.
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|
|
|
|||||
|
|
|
|
|
Restaurant terminal |
|
|
|
|